Do you have any question about this error?
Message type: E = Error
Message class: CJ - Project master data and structure
Message number: 544
Message text: Network type "&" does not exist
Network type &V1& either:
does not exist or
was not entered in the network profile
In either case, you cannot create activities.
INCLUDE 'NA_ALLG_NOVERARBEITUNG' OBJECT DOKU ID TX
INCLUDE 'NA_ALLG_MOEGLICH' OBJECT DOKU ID TX
RESET N1
Check your entries.
If necessary define the network type in Customizing the Project System
If necessary, enter a network type in the network profile.
You can also maintain the network type in scheduling using the menu
option <zh>Settings</>.
Error message extract from SAP system. Copyright SAP SE.
CJ544
- Network type "&" does not exist ?The SAP error message CJ544 indicates that the network type specified in a project or network activity does not exist in the system. This error typically occurs when you are trying to create or modify a network in Project System (PS) and the system cannot find the specified network type.
Cause:
- Incorrect Network Type: The network type you are trying to use may not be defined in the system.
- Configuration Issues: The network type may not be properly configured in the Project System settings.
- Authorization Issues: The user may not have the necessary authorizations to access the specified network type.
- Custom Development: If there are custom developments or modifications in the system, they may have affected the availability of the network type.
Solution:
Check Network Type: Verify that the network type you are trying to use is correctly defined in the system. You can do this by navigating to the configuration settings for network types in SAP:
- Use transaction code
OPRJ
to access the Project Management settings.- Check the configuration for network types to ensure that the specified type exists.
Create or Modify Network Type: If the network type does not exist, you may need to create it or modify an existing one. This can be done in the same configuration area mentioned above.
Check Authorizations: Ensure that the user has the necessary authorizations to create or modify networks. You can check this with your SAP security team or by reviewing the user roles and authorizations.
Consult Documentation: Review the SAP documentation or help files related to Project System and network types for additional guidance.
Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
CJ01
(Create Work Breakdown Structure), CJ02
(Change Work Breakdown Structure), and CJ20N
(Project Builder) for managing projects and networks.By following these steps, you should be able to resolve the CJ544 error and successfully work with network types in SAP Project System.
Get instant SAP help. Start your 7-day free trial now.
CJ543
No date changes exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CJ542
New start date is later than the old one
What causes this issue? You can only enter an earlier start date.System Response INCLUDE 'NA_ALLG_NOVERARBEITUNG' OBJECT DOKU ID TXError m...
CJ545
Date &1 is not a working day. Continue using &2?
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CJ546
Start date is in the past
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...