Do you have any question about this error?
Message type: E = Error
Message class: APB_FPM_CORE - FPM messages
Message number: 375
Message text: Dual quickview assignment at field &1
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
<DS:DE.FPM_QUICKVIEW_IMAGE_REF>More Information</>
Error message extract from SAP system. Copyright SAP SE.
APB_FPM_CORE375
- Dual quickview assignment at field &1 ?The SAP error message APB_FPM_CORE375, which states "Dual quickview assignment at field &1," typically occurs in the context of SAP Fiori applications or Web Dynpro applications that utilize the Floorplan Manager (FPM). This error indicates that there is a conflict in the configuration of quick views for a specific field, where two quick views are assigned to the same field.
Cause:
- Duplicate Quick View Assignments: The most common cause of this error is that two quick views are assigned to the same field in the FPM configuration. This can happen due to incorrect configuration or changes made to the application without proper validation.
- Configuration Errors: There may be issues in the FPM configuration where the same field is unintentionally linked to multiple quick views.
- Custom Development: If there are custom developments or enhancements made to the application, they might inadvertently create conflicts in the quick view assignments.
Solution:
Check FPM Configuration:
- Go to the FPM configuration for the application in question.
- Review the quick view assignments for the field indicated in the error message (replace &1 with the actual field name).
- Ensure that only one quick view is assigned to that field. If there are duplicates, remove or correct the assignments.
Debugging:
- If you are unable to find the issue in the configuration, consider debugging the application to trace where the quick views are being assigned.
- Check for any custom code that might be affecting the quick view assignments.
Transport Requests:
- If the issue arose after a transport, check the transport requests to ensure that the configurations were transported correctly and that no conflicting changes were made.
Consult Documentation:
- Refer to SAP documentation or notes related to FPM and quick views for any specific guidelines or known issues.
SAP Support:
- If the issue persists and you cannot resolve it, consider reaching out to SAP Support for assistance. Provide them with the error details and any relevant configuration information.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the APB_FPM_CORE375 error in your SAP application.
Get instant SAP help. Start your 7-day free trial now.
APB_FPM_CORE374
Value &1 is invalid
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
APB_FPM_CORE373
An error with configuration &1 occurred
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
APB_FPM_CORE376
Invalid image field assignment &1 at field &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
APB_FPM_CORE377
Enter a valid window name for Quickview &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.