Do you have any question about this error?
Message type: E = Error
Message class: AJ - Billing program
Message number: 654
Message text: DPC ESTB: Meter reading result determination at end of &2 has errors
When determining meter reading results within dynamic period control,
and there are no estimated meter reading results on the database (the
category of the current period = 1000 or 2000) an error occured in
function module ISU_DPC_IZWST_VIA_SIM_GET at the end of &V2& of period
&V1&-&V2& that is to be created. The exact cause of error is written in
the previous message and occured in function module
ISU_SIM_IZWST_ESTABLISH.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check the meter reading results for the installation. Contact SAP if
you cannot correct the error yourself.
Error message extract from SAP system. Copyright SAP SE.
AJ654
- DPC ESTB: Meter reading result determination at end of &2 has errors ?The SAP error message AJ654 indicates that there are issues with the determination of meter reading results at the end of a specific period (denoted by &2). This error typically arises in the context of SAP IS-U (Industry Solution for Utilities) when processing meter readings, particularly during the billing or closing processes.
Cause:
- Data Inconsistencies: There may be inconsistencies in the meter reading data, such as missing or incorrect readings.
- Configuration Issues: The configuration settings for meter reading results may not be set up correctly, leading to errors during the determination process.
- Master Data Issues: Problems with the master data related to the installation, such as incorrect or incomplete information about the meter or the customer.
- Technical Errors: There could be technical issues in the system, such as program errors or issues with the database.
Solution:
- Check Meter Readings: Review the meter readings for the relevant period to ensure that all readings are present and correct. Look for any missing or erroneous entries.
- Review Configuration: Verify the configuration settings for meter reading results in the SAP system. Ensure that all necessary parameters are correctly set.
- Validate Master Data: Check the master data for the relevant installations and meters. Ensure that all required fields are filled out correctly and that there are no inconsistencies.
- Analyze Logs: Look at the application logs or error logs in SAP to get more detailed information about the error. This can provide insights into what specifically went wrong during the determination process.
- Reprocess Meter Readings: If necessary, reprocess the meter readings or run the relevant transaction again after correcting any identified issues.
- Consult Documentation: Refer to SAP documentation or notes related to this error message for additional troubleshooting steps or patches that may be available.
Related Information:
By following these steps, you should be able to identify and resolve the underlying issues causing the AJ654 error message in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
AJ653
Values exist in the reversal period for installation &1 , operand &2
What causes this issue? The reversal was terminated because manual values were stored in the period &V3& to &V4& in the installation ...
AJ652
The to-date for &1 has been adjusted
What causes this issue? You have directly or indirectly adjusted the to-date of an operand value that was updated in the installation facts by automa...
AJ655
You cannot combine dynamic period ctrl &1 with budget billing amount
What causes this issue? You selected dynamic period control &V1&. You cannot combine this with the budget billing. The system issues an error...
AJ656
DPC ESTB: Meter reading result determ. for previous period has errors
What causes this issue? When determining meter reading results within dynamic period control, and there are no estimated meter reading results on the...
Click on this link to search all SAP messages.