Message text: Device &1 reg. &2 period &3-&4: measured press./air press./temp. missing
A volume correction factor procedure that requires calculation of
compressibility and/or supercompressibility through a user exit is
active. For this to occur, the following information must be complete
for the specified period:
Measured pressure
Air pressure
Temperature
An internal error occurred during the comparison of these time slices
with the time slices for the calorific value district (= gas
composition area).
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Please contact SAP.
Error message extract from SAP system. Copyright SAP SE.
AJ223
- Device &1 reg. &2 period &3-&4: measured press./air press./temp. missing ?The SAP error message AJ223 indicates that there is missing data related to measured pressure, air pressure, or temperature for a specific device and registration period. This error typically occurs in the context of SAP's Plant Maintenance (PM) or Environment, Health, and Safety (EHS) modules, where accurate measurements are crucial for operations and compliance.
Cause:
- Missing Measurement Data: The most common cause is that the required measurement data (pressure, air pressure, temperature) has not been recorded for the specified device and period.
- Incorrect Configuration: The device may not be properly configured to collect or report the necessary measurement data.
- Data Entry Errors: There may have been an oversight in data entry, leading to gaps in the recorded measurements.
- System Integration Issues: If the data is supposed to be pulled from another system (like a SCADA system), there may be integration issues preventing the data from being transferred correctly.
Solution:
- Check Measurement Records: Verify if the measurement data for the specified device and period has been entered correctly. If not, enter the missing data.
- Review Device Configuration: Ensure that the device is configured correctly to capture the required measurements. This may involve checking the settings in the SAP system or the physical device itself.
- Data Entry Correction: If there are errors in the data entry, correct them in the system to ensure that all required measurements are recorded.
- Integration Check: If the data is sourced from another system, check the integration points to ensure that data is being transferred correctly. This may involve working with IT or system administrators.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on handling measurement data for the relevant module.
Related Information:
By addressing the underlying causes and following the suggested solutions, you should be able to resolve the AJ223 error message in SAP.
Get instant SAP help. Start your 7-day free trial now.
AJ222
No register rate is allocated to rate type &1 and rate category &2
What causes this issue? Rate type &v1& is <DS:DE.USE_REGISTER>valid for registers</>. These wage types are usually assigned rates...
AJ221
Rate &1 permissibility does not correspond to permissibility for &2
What causes this issue? The following combinations of validity of rate and rate type are allowed: Val. rate type,,Valid rate Register,,<DS:DE.USE_...
AJ224
Rate determination created for rate type &1 and rate category &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AJ225
Rate determination changed for rate type &1 and rate category &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.