Do you have any question about this error?
Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 806
Message text: Enter standard temperature/zero temperature
You must maintain the constants for the <DS:DE.NTEMPB>standard
temperature</> and the <DS:DE.OTEMPB>zero temperature</> if the
temperature component is used for determining the volume correction
factor because these values are used in this calculation.
Maintain the values.
Error message extract from SAP system. Copyright SAP SE.
AH806
- Enter standard temperature/zero temperature ?The SAP error message AH806, which states "Enter standard temperature/zero temperature," typically occurs in the context of handling materials and their properties, particularly in the area of material master data or when dealing with temperature-dependent properties in SAP.
Cause:
The error is usually triggered when:
- Missing Data: The standard temperature or zero temperature values are not maintained in the material master record for a specific material.
- Incorrect Configuration: The system expects these values to be defined for certain processes, such as when calculating physical properties or during the handling of specific materials that require temperature considerations.
- Data Entry Error: There may be a mistake in the data entry process where the required fields were left blank or incorrectly filled.
Solution:
To resolve the AH806 error, you can take the following steps:
Check Material Master Data:
- Go to the material master record (transaction code
MM02
for change orMM03
for display).- Navigate to the relevant views (e.g., Basic Data, Plant Data, or any specific view related to temperature).
- Ensure that the fields for standard temperature and zero temperature are filled in correctly.
Maintain Required Fields:
- If the fields are empty, enter the appropriate values. The standard temperature is typically set to 20°C (or 68°F), but this can vary based on your organization's standards.
- Save the changes and try the process again that triggered the error.
Check Configuration:
- If you have access, check the configuration settings in the SAP system to ensure that the temperature-related fields are correctly set up and required for the materials you are working with.
Consult Documentation:
- Review any relevant SAP documentation or internal guidelines that pertain to material handling and temperature settings to ensure compliance with your organization's practices.
Contact Support:
- If the issue persists after checking the material master and configuration, consider reaching out to your SAP support team or a functional consultant for further assistance.
Related Information:
MM01
(Create Material), MM02
(Change Material), and MM03
(Display Material) for managing material master data.By following these steps, you should be able to resolve the AH806 error and ensure that your material master data is correctly maintained.
Get instant SAP help. Start your 7-day free trial now.
AH805
Position cursor on a device or register
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AH804
Billing unit of measurement could not be determined
Aug.2012: syntax of V1 .. V4 corrected, but text as such unchanged.What causes this issue? No billing unit of measurement could be determined from t...
AH807
Not possible to maintain standard temperature/zero temperature
What causes this issue? In most cases you can only maintain a standard temperature/zero temperature if the temperature component is used in the volum...
AH808
Time basis and time cat. required when you enter consumption or amount
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.