How To Fix AH076 - Gas procedure &1 not in table &2


AH076 - Overview

  • Message type: E = Error

  • Message class: AH - IS-U billing (master data)

  • Message number: 076

  • Message text: Gas procedure &1 not in table &2

  • Show details Hide details
  • What causes this issue?

    The specified gas procedure does not exist.

    System Response

    How to fix this error?

    If gas procedure " " appears in the message, than <ZH>no</> gas
    procedure was reported. Make sure a gas procedure has been maintained
    at register level. A <ZH>valid</> gas procedure must be entered at
    register level. For more information, please refer to the following
    <DS:DE.THGVER>note</>, which also illustrates how to check all the
    gas-relevant data for the affected device/register.
    Please note the following:
    Gas billing procedures are generally processed in the <DS:TRAN.EA74>Gas
    Procedure</> transaction.
    Settings for gas customizing are configured in the Implementation Guide
    <DS:CHAP._ISUBISFGA_000001>(IMG)</>.

    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message AH076 - Gas procedure &1 not in table &2 ?
    The SAP error message AH076, which states "Gas procedure &1 not in table &2," typically occurs in the context of gas measurement and billing processes within the SAP system, particularly in the Utilities Industry (IS-U module). This error indicates that the system is trying to reference a gas procedure that is not defined in the specified table.
    
    Cause: Missing Configuration: The gas procedure specified in the error message (&1) is not defined in the relevant configuration table (&2). This could be due to a missing entry or an incorrect configuration. Data Migration Issues: If data has been migrated from another system or if there have been recent changes to the configuration, it is possible that the necessary entries were not migrated or were deleted. Incorrect Input: The error may also arise from incorrect input or data entry that references a non-existent gas procedure.
    Solution: Check Configuration: Go to the relevant configuration transaction in SAP (e.g., SPRO) and

    Already have an account? Login here!




Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker