Do you have any question about this error?
Message type: E = Error
Message class: AD - Data Dictionary application messages
Message number: 549
Message text: Error in technical settings for table &
The technical settings for the table could not be activated.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
AD549
- Error in technical settings for table & ?The SAP error message AD549 indicates that there is an issue with the technical settings of a database table in the SAP system. This error typically arises during the creation or modification of a table in the Data Dictionary (SE11) or when trying to activate a table that has not been properly configured.
Cause:
The error can be caused by several factors, including:
- Incorrect Technical Settings: The technical settings for the table may not be properly defined, such as the data class, size category, or buffering settings.
- Missing or Incorrect Table Attributes: Attributes like primary keys, foreign keys, or indexes may not be correctly set up.
- Database Issues: There may be underlying issues with the database itself, such as connectivity problems or database constraints.
- Authorization Issues: The user may not have the necessary authorizations to make changes to the table settings.
Solution:
To resolve the AD549 error, you can follow these steps:
Check Technical Settings:
- Go to transaction SE11 and enter the table name.
- Click on "Technical Settings" and review the settings for the data class, size category, and buffering.
- Ensure that the settings are appropriate for the table's intended use.
Review Table Attributes:
- Ensure that all required fields are defined correctly, including primary keys and any foreign key relationships.
- Check for any inconsistencies in the field definitions.
Activate the Table:
- After making the necessary adjustments, try to activate the table again. You can do this by clicking on the "Activate" button in SE11.
Check for Database Issues:
- If the problem persists, check the database logs for any errors or issues that may be affecting the table.
- Ensure that the database is running correctly and that there are no connectivity issues.
Authorization Check:
- Verify that the user has the necessary authorizations to create or modify tables in the Data Dictionary.
Consult SAP Notes:
- Check the SAP Support Portal for any relevant SAP Notes that may address this specific error or provide additional troubleshooting steps.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the AD549 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
AD548
Technical settings for table & activated
What causes this issue? The technical settings for tables include information such as buffering type, logging of table contents, memory sizes for the...
AD547
Technical settings for table & modified/generated
What causes this issue? During activation of the table it was found that the appropriate entry relating to the buffer was missing from the technical ...
AD550
Table & cannot be displayed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AD551
Generic entry not possible for numeric field types
What causes this issue? You entered a character in the selection condition that is not allowed in numeric fields.System Response Your entry is rejec...
Click on this link to search all SAP messages.