Do you have any question about this error?
Message type: E = Error
Message class: 55 - Messages for development class EENO
Message number: 226
Message text: Modification group in field group &1 ignored due to subscreen &2
This subscreen (&V2&) is linked to a <DS:DE.TA_FELDGRP>field group</>
(&V1&). It is therefore not necessary to furnish the
<DS:DE.TA_MODIF>modification group field</> with data. This field is
ignored.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
55226
- Modification group in field group &1 ignored due to subscreen &2 ?The SAP error message 55226, which states "Modification group in field group &1 ignored due to subscreen &2," typically occurs in the context of screen modifications in SAP, particularly when dealing with subscreens and field groups.
Cause:
This error arises when there is a conflict between the modification group defined for a field group and the subscreen that is being used. Specifically, it indicates that the modification group specified for a field group is not applicable or is being ignored because the field group is part of a subscreen. In SAP, subscreens are used to modularize screen layouts, and certain modifications may not be allowed or applicable in these contexts.
Solution:
To resolve this error, you can take the following steps:
Check Modification Group Settings:
- Review the modification group assigned to the field group in question. Ensure that it is correctly defined and that it is intended to be used in the context of the subscreen.
Review Subscreen Configuration:
- Check the configuration of the subscreen (subscreen &2 in the error message). Ensure that it is set up correctly and that it is compatible with the field group.
Adjust Field Group:
- If the field group is not meant to be modified in the context of the subscreen, consider removing or adjusting the modification group settings for that field group.
Consult Documentation:
- Refer to SAP documentation or notes related to screen modifications and subscreens to understand any limitations or specific configurations that may apply.
Debugging:
- If you have access to the development environment, you can debug the screen to see how the field group and subscreen are being processed. This may provide insights into why the modification group is being ignored.
SAP Notes:
- Check the SAP Support Portal for any relevant SAP Notes that may address this specific error or provide additional guidance.
Related Information:
If the issue persists after following these steps, it may be beneficial to consult with an SAP technical consultant or developer who can provide more in-depth analysis and support.
Get instant SAP help. Start your 7-day free trial now.
55225
Create linked field group &3 for subscreen & 2 (field group: &1)
What causes this issue? This field group (&V3&), to which subscreen &V2& has been linked, does not exist.System Response The system ...
55224
Specify a maximum of &1 pages in view &3; currently (&2)
What causes this issue? In this view (&V3&) you have defined more pages (&V2&) than the permitted maximum number (&V1&).Syste...
55227
Optional flag in field group &1 ignored due to subscreen &2
What causes this issue? This subscreen (&V2&) is linked to a <DS:DE.TA_FELDGRP>field group</> (&V1&). It is therefore not...
55228
Do not use field group &1 in page &2
What causes this issue? This <DS:DE.TA_FELDGRP>field group</> (&V1&) is linked to another field group. Thus you cannot use this f...
Click on this link to search all SAP messages.