Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: SY - ABAP/4 system messages
Message number: 373
Message text: Fehler Nr. &1 beim Übernehmen des Ergebnisses eines OLE Aufrufs.
The system could not assign the results of an OLE Automation call to
the correct program variables.
Meanings of the error number <(>&<)>1:
-1: The event memory of the automation queue is destroyed - internal
error
1: There is no valid link to the program variables (PcbInvalidId)
2: The link cannot be expanded (PcbInternal)
3: The link points to an internal table that has been cleared
(PcbItabFreed)
4: The link points to a local variable whose stack frame has been
released (PcbStackFreed).
Note: Errors 3 and 4 indicate a programming error. When you program
with controls, you must ensure that the return value (for example, the
selected node of a tree) is not written into a local variable. For
performance reasons, control calls are not necessarily sent to the
front end imnmediately, but are placed in a queue instead. The queue
may be sent to the frontend at a point where the local variable no
longer exists because, for example, the call occurred in a subroutine
that had ended by the time the queue was flushed. Avoid control calls
with local importing parameters.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
The system assumes that correct processing is no longer possible
without the return value. To be on the safe side, it stops processing.
Depending on the kind of error, the application program may need
correcting (error number 3 or 4) or a system error occurred while
processing the automation queue (SAP Automation Controller).
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
SY373
- Fehler Nr. &1 beim Übernehmen des Ergebnisses eines OLE Aufrufs. ?Get instant SAP help. Sign up for our Free Essentials Plan.
SY372
Keine Berechtigung zum Ändern der Speicherwerte
Was verursacht dieses Problem? You must have the appropriate authorization to set the values.Wie behebe ich diesen Fehler? You need the authoriza...
SY371
OLE-Verb & nicht in TypeInfo gefunden.
Was verursacht dieses Problem? Type information describes all methods and properties of an OLE server and must be loaded into the R/3 System, befor...
SY374
Spool-Auftrag (Nummer &) an SAP-Drucker & gesendet
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
SY375
Spool-Auftrag (Nummer &) an Archiv gesendet
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.