Do you have any question about this error?
Message type: E = Error
Message class: SV - View Maintenance: Customize Messages
Message number: 585
Message text: Das Viewcluster enthält Teildialoge mit und ohne Navigations-Subscreen.
From Release 46A view cluster navigation uses a Tree Control.
The navigation subscreen is no longer put in the view maintenance
screens of new maintenance dialogs in a modified view cluster when it
activated. Existing subscreens are dynamically compressed away at
runtime.
This view cluster &V1& contains maintenance dialogs both with and
without navigation subscreens.
The view cluster is activated nevertheless. The navigation subscreens
are not active at runtime.
You can delete the navigation subscreens in the view maintenance
screens as follows:
Reactivate the view cluster and confirm the deletion of the subscreen
in the 'View cluster navigation' popup.
Use the program <LS>RSVCLNAVI</> to delete the navigation subscreen
from the screen.
The program can also edit all the view clusters in a package.
You can also delete the subscreens from the view maintenance dialogs
manually in the Screen Painter.
Note:
Navigation subscreens in maintenance dialog detail screens must always
be removed manually in the Screen Painter, because they are not
inserted automatically. User modules for navigating in detail screens
must also be removed manually.
Possible incompatibilities using the Tree Control:
Manipulation in user-defined events of the global internal table
<LS>VCL_STRUC_TAB</> to influence the navigation subscreen structure
may not affect the Tree Control structure.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
SV585
- Das Viewcluster enthält Teildialoge mit und ohne Navigations-Subscreen. ?Get instant SAP help. Start your 7-day free trial now.
SV584
& ist eine Viewcluster-Variante
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
SV583
Keine Feldabhängigkeit vom Typ 'I' für Feld & des Objektes & möglich
Was verursacht dieses Problem? &V1& was specified as field name in a field relationship of type 'I' for the object &V2&, ...
SV586
Dynpro & konnte nicht aktiviert werden.
Was verursacht dieses Problem? Screen &V1& has been modified for view cluster maintenance and saved. Screen activation errors occurred, whi...
SV587
Objekt & ist eine Pflegeview-Variante. Dynpro wurde nicht geändert.
Was verursacht dieses Problem? The object &V1& is a maintenance view variant of &V2& so it has no maintenance screens of its own.Sy...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.