Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 323
Message text: Lesen Sie die IMG-Dokumentation vor Aktivieren der SAP-Erdgasroutinen.
Activate SAP conversion routines for natural gas
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
In order to use the SAP conversion routines for natural gas, you have toThe system continues processing.
To be able to confirm the correctness of the SAP routines, you have to:
1. Check the constants defined in include LOIB_QCITOC.
2. Check the natural gas routines
Approve the following form routines that are located in function
group OIB_QCI:
a) CALCULATE_GAS_BASE_DENSITY (based on ISO 13443, first
edition 1996-12-15)
b) CALCULATE_GAS_BASE_HEATING_VAL (based on ISO 13443, first
edition 1996-12-15)
c) CALCULATE_IDEAL_GAS_VCF (based on ISO 13443, first edition
1996-12-15)
d) CALC_COMBUSTION_CORRECTION (based on ISO 13443, first
edition 1996-12-15)
e) DENSITY_HVALUE_CONVERSION (based on ISO 6976, 1995-12-01,
corrected and reprinted 1996-02-01)
,,Method DETERMINE_AIR_COMP_FAC has to be implemented if base conditions
are used in a conversion ,,group other than the set of conditions
specified in ISO 6976, 1995-12-01, Annex B. This method has to pass the
,,compression factor of air at the new base condition set back to the
form DENSITY_HVALUE_CONVERSION.
3. Check the handling of the results from the AGA C-code routines
(if activated) in form routines ,,DO_EXTERNAL_CALL and
DO_EXTERNAL_CALL_2.
If you decide not to activate the SAP conversion routines, proceed as
follows:
1. Define your own new constants.
2. Implement the following methods if natural gas quantity conversion
has to be performed by the QCI. Each of these 5 routines replace
one of the above-mentioned form routines. The methods are part of the
business add-in OIB_NATURAL_GAS:
a) CALC_BASE_DENSITY
b) CALC_BASE_HEATINGVALUE
c) CALC_IDEAL_GAS_VCF
d) CORR_COMBUSTION_ENERGY
e) DENSITY_HVALUE_CONVERT
The methods can also be used to modify the results from the SAP
conversion routines.
3. Implement method DETERMINE_Z_FACTOR.
If the SAP conversion routines are activated, the SAP system retrieves
the compression factors at ambient and at the base conditions from the
AGA C-code. It calculates a combined volume correction factor by
multiplying the ideal gas volume correction factor with the compression
factor at base conditions and dividing this result by the compression
factor at ambient conditions (material temperature and pressure).
If the SAP conversion routines are not activated, method
DETERMINE_Z_FACTOR is called instead. It imports the results from the
AGA C-code and changes a combined volume correction factor according to
the customer-specific coding.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
O3323
- Lesen Sie die IMG-Dokumentation vor Aktivieren der SAP-Erdgasroutinen. ?Get instant SAP help. Start your 7-day free trial now.
O3322
Interne Tabelle & ist leer; Verarbeitung beendet: Verwaltung verständigen
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
O3321
Umrechnungsgruppe ist bereits einem aktiven Liefernetz zugeordnet.
Was verursacht dieses Problem? The conversion group is already assigned to a delivery network. Entries can not be changed.Systemantwort Das Syste...
O3324
Unerwartete interne Tabelle: &.
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
O3325
Dieser Vorschlagswertsatz ist aktiv: Ändern oder Löschen nicht möglich
Was verursacht dieses Problem? The new default parameter transaction allows you to create default sets for several materials at once. It also intro...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.